16A Satu Tembakan Sekering Pemotong Termal Cross UL VDE Sekering Termal Microtemp
Detail produk:
Tempat asal: | Dongguan, Guangdong, Cina |
Nama merek: | AMPFORT |
Sertifikasi: | UL,CUL,VDE,CCC |
Nomor model: | BF121X |
Syarat-syarat pembayaran & pengiriman:
Kuantitas min Order: | 1000 buah |
---|---|
Harga: | Negotiable |
Kemasan rincian: | Jumlah besar |
Waktu pengiriman: | 7-10 Hari Kerja |
Syarat-syarat pembayaran: | T / T, paypal, western union |
Menyediakan kemampuan: | 10.000.000 Potongan Per Bulan |
Informasi Detail |
|||
Nama: | Sekering Termal Sekali Pakai 16A 250V 121C Cutoff | Suhu Fungsi: | 121°C |
---|---|---|---|
Terminal sekering: | bertimbal aksial | Memegang Suhu: | 106°C |
Peringkat Tegangan VAC: | 250v | Sekring Saat Ini: | 16A |
Ukuran: | 4x11mm | Kode HS: | 8536100000 |
Cahaya Tinggi: | 16A Thermal Cutoff Fuse,250V satu tembakan Thermal Cutoff Fuse,Cross UL VDE microtemp thermal fuse |
Deskripsi Produk
MICROTEMP G5A01121C Cross UL VDE CCC Satu-shot Thermal Fuse 16A 250V 121C Cutoff
Deskripsi Sekering Termal Sekali Pakai 16A 250V 121C Cutoff
Seri G5 MICROTEMP cross dari Ampfort berukuran ringkas, pemutus termal standar global.Sekering termal AMPFORT menawarkan solusi yang akurat dan andal untuk perlindungan suhu batas atas terhadap panas berlebih.Pemutus termal ini mengganggu sirkuit listrik ketika suhu operasi melebihi suhu pengenal sekering termal.Pemutus termal seri BFX dirancang untuk aplikasi tegangan dan arus yang lebih tinggi.Pengakuan agensi global dari seri BFX memungkinkan penggunaan dalam berbagai aplikasi termasuk peralatan utama dan HVAC.Seri ini memiliki konstruksi internal berbeda yang dirancang untuk memutus arus yang lebih tinggi dan menahan suhu yang lebih tinggi.
Pertunjukan Sekering Termal Sekali Pakai 16A 250V 121C Cutoff
Model nomor. | Tf(℃) |
Sekering-off Suhu (℃) |
T(℃) | Tm(℃) | Ir(A) | Ur(V) | |
IEC | perusahaan | ||||||
BF73X | 73 | 73+0/-10 | 70±2 | 58 | 200 | 16 | 250 |
BF77X | 77 | 77+0/-10 | 74±2 | 62 | 300 | 16 | 250 |
BF84X | 84 | 84+0/-10 | 82±2 | 69 | 300 | 16 | 250 |
BF94X | 94 | 94+0/-10 | 90±2 | 79 | 300 | 16 | 250 |
BF99X | 99 | 99+0/-10 | 95±2 | 84 | 300 | 16 | 250 |
BF104X | 104 | 104+0/-10 | 101+2/-3 | 90 | 210 | 16 | 250 |
BF113X | 113 | 113+0/-10 | 110±2 | 98 | 400 | 16 | 250 |
BF117X | 117 | 117+0/-10 | 114±2 | 102 | 400 | 16 | 250 |
BF121X | 121 | 121+0/-10 | 118±2 | 106 | 400 | 16 | 250 |
BF133X | 133 | 133+0/-10 | 131+2/-3 | 119 | 400 | 16 | 250 |
BF142X | 142 | 142+0/-10 | 138+2/-3 | 127 | 400 | 16 | 250 |
BF157X | 157 | 157+0/-10 | 155±2 | 142 | 400 | 16 | 250 |
BF172X | 172 | 172+0/-10 | 169+2/-3 | 157 | 400 | 16 | 250 |
BF184X | 184 | 184+0/-10 | 181±2 | 169 | 400 | 16 | 250 |
BF192X | 192 | 192+0/-10 | 189±2 | 177 | 400 | 16 | 250 |
BF216X | 216 | 216+0/-10 | 212±2 | 191 | 450 | 16 | 250 |
BF229X | 229 | 229+0/-10 | 226±2 | 201 | 450 | 16 | 250 |
BF240X | 240 | 240+0/-10 | 235±3 | 201 | 450 | 16 | 250 |
BF257X | 257 | 257+0/-10 | 254±2 | 200 | 470 | 16 | 250 |
Ukuran Sekering Termal Sekali Pakai 16A 250V 121C Cutoff (mm)
model nomor | Sebuah | B | C | D | e | F |
BFX | 20±1.0 | 11±1.0 | 35±1.0 | 1.0±0.1 | 4.0±0.1 | 1.0±0.1 |
Sertifikasi Sekering Termal Sekali Pakai 16A 250V 121C Cutoff
Model nomor. | UL/CUL | VDE | CCC |
BF73X | E140847 | 40005418 | 2003010205052188 |
BF77X | |||
BF84X | |||
BF94X | |||
BF99X | |||
BF104X | |||
BF113X | |||
BF117X | |||
BF121X | |||
BF133X | |||
BF142X | |||
BF157X | |||
BF172X | |||
BF184X | |||
BF192X | |||
BF216X | |||
BF229X | |||
BF240X | |||
BF257X | ○ | ○ |
Perlindungan Suhu Batas Atas Dari Sekering Termal Sekali Pakai 16A 250V 121C Cutoff
Pemutus termal Ampfort menawarkan solusi yang akurat dan andal untuk kebutuhan perlindungan suhu batas atas.Dikenal sebagai sekering termal, tautan termal, atau TCO, pemutus termal memberikan perlindungan terhadap panas berlebih dengan memutus sirkuit listrik saat suhu pengoperasian melebihi suhu pengenal pemutus.
Fitur Utama Sekering Termal Sekali Pakai 16A 250V 121C Cutoff
• Kapasitas interupsi saat ini hingga 16A pada 250VAC
• Suhu fungsi (Tf) berkisar dari 72°C hingga 240°C
• Tersedia dalam lead yang dipotong, dibentuk atau diakhiri
• Opsi terpasang dan pot tersedia
• UL/CUL, VDE, CCC disetujui
• Operasi sekali tembak memutus aliran listrik
• Resistensi rendah
• Ukuran ringkas
Penerapan Sekering Termal Sekali Pakai 16A 250V 121C Cutoff
* Industri
* Keamanan
* Perangkat Portabel
* Elektronik Konsumen
Prinsip Operasi TCO Sekering Termal Sekali Pakai 16A 250V 121C Cutoff
Mekanisme pemicu aktif dari pemutus termal adalah pelet nonkonduktif elektrik yang diformulasikan secara eksklusif.Di bawah suhu operasi normal, pelet padat menahan kontak pegas tertutup.Ketika suhu yang telah ditentukan tercapai, pelet meleleh, memungkinkan pegas kompresi untuk bersantai.Pegas trip kemudian menggeser kontak menjauh dari lead dan sirkuit dibuka (lihat gambar 1 dan 2).Setelah pemutus termal membuka sirkuit, TCO perlu diganti.Prosedur penggantian ini harus mencakup koreksi kondisi kesalahan sebelum produk dioperasikan kembali.
Lebih Banyak Bagian Dari Sekering Termal Sekali Pakai 16A 250V 121C Cutoff